[U(mV)-T(°C) calibration]
FitMethod = Polynom
TransformX = Line
TransformY = GOST_TC_A2
Power = 1
Center = 0
Scale = 1
Fixed = 1
Coeff[0] = 0
Coeff[1] = 1
Bounds = 0.000 27.232
Data U(mV)  T(°C)  Weight Tcj(°C)
     0.000  0      1      0
     1.338  100    1      0
     2.902  200    1      0
     4.571  300    1      0
     6.280  400    1      0
     7.998  500    1      0
     9.707  600    1      0
     11.398 700    1      0
     13.064 800    1      0
     14.696 900    1      0
     16.289 1000   1      0
     17.835 1100   1      0
     19.330 1200   1      0
     20.774 1300   1      0
     22.168 1400   1      0
     23.515 1500   1      0
     24.814 1600   1      0
     26.059 1700   1      0
     27.232 1800   1      0
End Data
Notice Text
Standard calibration of thermocouple type A2 (W-5%Re/W-20%Re) ТВР-A2 вольфрам/рений wolfram/rhenium
Reference source: GOST R 8.585—2001, Table 10
Configuration example:
Link AnalogInput  0 with curve ThermoCoupleVoltage(mV)
Link AnalogInput  1 with curve TemperatureColdJunction(°C)
Link AnalogOutput 0 with curve TemperatureThermoCouple(°C) history 100
Calibration#0 = ~~\Resource\DaqSite\StdLib\Calibr\_GOST_TC_A2.CAL U(mV) T(°C) Tcj(°C) Line GOST_TC_A2 0.000 27.232